Trigger settings#

Trigger Mode#

Key hold (level)#

Press the button to trigger the reading, release the button to end the reading; after the reading is successful or the single reading time times out, the reading ends.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2050200.png

* Key hold (level)#

Single key trigger (pulse)#

Reading begins after a change in key level is detected and maintained for about 30 ms (the specific time depends on the product); reading ends when a change in key level is detected again. This reading ends after the reading is successful or the single reading time times out.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2050202.png

Single key trigger (pulse)#

Continuous Mode#

The reading engine works continuously; each time the reading is successful or the single reading time expires, the reading ends, and the next reading is automatically triggered after the continuous reading interval is reached.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2050204.png

Continuous Mode#

Auto sensing mode#

The reading engine detects the brightness of the surrounding environment and triggers reading when the brightness changes. After the reading is successful or the single reading time times out, the current reading ends and the environment brightness detection is re-entered.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2050209.png

Auto sensing mode#

Single scan time (scan duration)#

Set the maximum duration of a single scan. After scanning this setup code, scan three numeric setup codes to enter the time coefficient. If the value has fewer than three digits, pad it with leading 0.

Default

3000 ms

Unit

100 ms

Range

500-25500 ms

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30500305FF.png

Single scan time#

Example

To set 500 ms, scan this setup code, then scan numeric setup codes 0, 0, and 5 in sequence.

To set 10500 ms, scan this setup code, then scan numeric setup codes 1, 0, and 5 in sequence.

To change a selection or cancel an incorrect setting, scan Cancel Barcode.

Single Scan Time (Scan Duration) Quick Setup#

To select a commonly used duration directly, scan one of the quick setup barcodes below.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030CF0.png

Unlimited#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030CF3.png

3 s#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030CF5.png

5 s#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030CFA.png

10 s#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030CFB.png

15 s#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030CFC.png

20 s#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030CFD.png

30 s#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030CFE.png

60 s#

Continuous reading interval#

In Continuous Mode, this parameter defines the wait time between two scan attempts. After the configured interval elapses, the next scan starts automatically whether the previous attempt succeeded or failed.

After scanning this setup code, scan two numeric setup codes to enter the time coefficient. If the value has fewer than two digits, pad it with a leading 0.

Default

500 ms

Unit

100 ms

Range

0-9900 ms

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3050120063.png

Continuous reading interval#

Example

To set 500 ms, scan this setup code, then scan numeric setup codes 0 and 5 in sequence.

To change a selection or cancel an incorrect setting, scan Cancel Barcode.

Same code delay#

To prevent the same barcode from being decoded repeatedly in Continuous Mode or Auto-sense Mode, you can require the decode engine to wait for the configured delay before reading the same barcode again.

After scanning this setup code, scan two numeric setup codes to enter the time coefficient. If the value has fewer than two digits, pad it with a leading 0.

Default

500 ms

Unit

100 ms

Range

0-9900 ms

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3F30000003.png

Same code delay#

Example

To set 200 ms, scan this setup code, then scan numeric setup codes 0 and 2 in sequence.

To set 1500 ms, scan this setup code, then scan numeric setup codes 1 and 5 in sequence.

To change a selection or cancel an incorrect setting, scan Cancel Barcode.

Same code delay quick setting#

To select a commonly used same-code delay directly, scan one of the quick setup barcodes below. Six preset levels are available: 0 s, 1 s, 3 s, 5 s, 7 s, and unlimited delay.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030C90.png

No delay#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030C91.png

1 s Delay#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030C93.png

3 s Delay#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030C95.png

5 s Delay#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030C97.png

7 s Delay#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030C99.png

Unlimited Delay (Disable Same-Code Reads)#