Barcode Settings

Contents

Barcode Settings#

Common Symbology Entries#

Symbology

Entry

UPC-A

UPC-A

UPC-E

UPC-E

EAN-8

EAN-8

EAN-13

EAN-13

Bookland EAN

Enable/disable Bookland EAN (ISBN)

Code 128

Code 128

GS1-128

GS1-128 (formerly UCC/EAN-128)

Code 39

Code 39

Code 93

Code 93

Code 11

Code 11

Interleaved 2 of 5

Interleaved 2 of 5/ITF/Crossed 25 yards

Codabar

Codabar

MSI

MSI/MSI PLESSEY

PDF417

PDF417

QR Code

QR Code

Data Matrix

Data Matrix (DM)

Maxi Code

Maxi Code

Aztec Code

Aztec Code

Han Xin Code

Han Xin Code

1D inverted barcode reading#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030910.png

* Disable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030911.png

Enable#

Barcode global switch#

One-dimensional code switch#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030110.png

Disable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030111.png

Enable#

QR code switch#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030500.png

Disable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030501.png

Enable#

All barcode switches#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030900.png

Disable all barcodes#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030901.png

Enable all barcodes#

Linear code type safety level#

The reading engine provides four levels of decoded security linear encoding types. Select a higher security level for declining barcode quality levels. Follow

As the security level increases, the reading engine becomes less aggressive. Choose the security level that suits your barcode quality.

Linear safety level 1#

All code types must be successfully read 1 time before being decoded

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2051501.png

* Linear safety level 1#

Linear safety level 2#

All code types must be read successfully 2 times before being decoded.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2051502.png

Linear safety level 2#

Linear safety level 3#

All code types must be successfully read 3 times before being decoded.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2051503.png

Linear safety level 3#

Linear safety level 4#

All code types must be successfully read 4 times before being decoded

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2051504.png

Linear safety level 4#

UPC-A#

Enable/disable UPC-A#

Scan the corresponding barcode below to enable or disable UPC-A.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000011.png

* Enable UPC-A#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000010.png

Disable UPC-A#

UPC-A preamble#

Preamble characters (country code and system characters) may be transmitted as part of the UPC-A code system. Select one of the following options to set and transmit the UPC-A preamble to the host: transmit system characters only, transmit system characters and country code (“0” for United States), or transmit no preamble.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2030100.png

No preamble (<DATA>)#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2030101.png

* System characters (<SYSTEM CHARACTER> <DATA>)#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2030102.png

System characters & country code (<COUNTRY CODE> <SYSTEM CHARACTER> <DATA>)#

Transmit UPC-A check digit#

Scan the corresponding barcode below to set whether to transmit the UPC-A check code.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020021.png

* Transmit UPC-A check digit#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020020.png

Do not transmit UPC-A check digit#

UPC-A 2-digit add-on code#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030401.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030400.png

* Disable#

UPC-A 5-digit add-on code#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030411.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030410.png

* Disable#

UPC-A must read additional code#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030421.png

To enable UPC-A, the additional code must be read#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030420.png

Disable UPC-A Additional code must be read#

UPC-E#

Enable/disable UPC-E#

Scan the corresponding barcode below to enable or disable UPC-E.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000021.png

* Enable UPC-E#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000020.png

Disable UPC-E#

UPC-E preamble#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2030000.png

No preamble (<DATA>)#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2030001.png

* System characters (<SYSTEM CHARACTER> <DATA>)#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2030002.png

System characters & country code (<COUNTRY CODE> <SYSTEM CHARACTER> <DATA>)#

Transmit UPC-E check digit#

Scan the corresponding barcode below to set whether to transmit the UPC-E check digit.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020031.png

* Transmit UPC-E check digit#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020030.png

Do not transmit UPC-E check digit#

Convert UPC-E to UPC-A#

This parameter allows this parameter to be converted from UPC-E (zero suppression) decoded data to UPC-A format before transmission. After conversion, the data follows UPC-A format and is protected by UPC-A

Impact of programming choices (eg: preamble, checksum).

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020001.png

Convert UPC-E to UPC-A#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020000.png

* Does not convert UPC-E to UPC-A#

UPC-E 2-digit add-on code#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30303D1.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30303D0.png

* Disable#

UPC-E 5-digit add-on code#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30303E1.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30303E0.png

* Disable#

UPC-E must read additional codes#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30303F1.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30303F0.png

* Disable#

UPC-E1 switch#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030150.png

* Disable UPC-E1#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030151.png

Enable UPC-E1#

EAN-8#

Enable/disable EAN-8#

Scan the corresponding barcode below to enable or disable EAN-8.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000041.png

* Enable EAN-8#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000040.png

Disable EAN-8#

EAN-8 zero extension#

When this parameter is enabled, this parameter plus 5 leading 0s decodes EAN-8 to make it compatible with the EAN-13 format. When this parameter is disabled, the EAN-8 code system is transmitted

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020011.png

Enable EAN-8 zero extension#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020010.png

* Disable EAN-8 zero extension#

EAN-8 2-digit additional code#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030371.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030370.png

* Disable#

EAN-8 5-digit add-on code#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030381.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030380.png

* Disable#

EAN-8 must read additional code#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030391.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030390.png

* Disable#

EAN-8 sends check digit#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030800.png

Disable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030801.png

* Enable#

EAN-13#

Enable/disable EAN-13#

Scan the corresponding barcode below to enable or disable EAN-13.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000031.png

* Enable EAN-13#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000030.png

Disable EAN-13#

EAN-13 2-digit additional code#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30303A1.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30303A0.png

* Disable#

EAN-13 5-digit add-on code#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30303B1.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30303B0.png

* Disable#

EAN-13 must read additional code#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30303C1.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30303C0.png

* Disable#

EAN-13 send check character#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030160.png

Disable EAN-13 sending check characters#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030161.png

Enable EAN-13 to send check characters#

Enable/disable Bookland EAN (ISBN)#

Scan the corresponding barcode below to enable or disable Bookland EAN (ISBN).

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000231.png

Enable Bookland EAN#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000230.png

* Disable Bookland EAN#

Code 128#

Note

The enable/disable control of Code 128 also applies to AIM128; the output type identification of AIM128 is different from that of ordinary Code 128.

Enable/disable Code 128#

Scan the corresponding barcode below to enable or disable Code 128.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000101.png

* Enable Code 128#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000100.png

Disable Code 128#

Code 128 Send check character#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030351.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030350.png

* Disable#

Code 128 length setting#

Allows reading of Code 128 codes of a specific length. After scanning the length setting barcode, scan the 4-digit setting barcode to set L1 and L2; L1 and L2 each occupy 2 digits. If there are less than 2 digits, add 0 in front.

When scanning the “Code 128 Any Length” setting barcode, any length can be read, and there is no need to scan the numeric setting barcode.

Default

0-99

Set range

01-99

condition

Description

L1 < L2

L1 is the minimum length, L2 is the maximum length

L1 > L2

L1 is the maximum length, L2 is the minimum length

L1 = L2

Only read fixed length

Example

Only 4-8 characters are allowed to be read: scan the numeric setting barcode 0, 4, 0, 8, or 0, 8, 0, 4.

Fixed reading of 12 characters: Scan the numeric setting barcodes 1, 2, 1, 2.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F3118485F50000005.png

Code 128 any length#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F0118485F50000005.png

Code 128 specifies the length#

GS1-128 (formerly UCC/EAN-128)#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1040331.png

GS1-128 (formerly UCC/EAN-128)#

any length

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1040330.png

* Enable GS1-128#

Disable GS1-128

UCC/EAN-128 sending check characters#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030361.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030360.png

* Disable#

UCC/EAN-128 length setting#

Allows reading of UCC/EAN-128 codes of specific lengths. After scanning the length setting barcode, scan the 4-digit setting barcode to set L1 and L2; L1 and L2 each occupy 2 digits. If there are less than 2 digits, add 0 in front.

When scanning the “UCC/EAN-128 Any Length” setting barcode, any length can be read, and there is no need to scan the numeric setting barcode.

Default

0-99

Set range

01-99

condition

Description

L1 < L2

L1 is the minimum length, L2 is the maximum length

L1 > L2

L1 is the maximum length, L2 is the minimum length

L1 = L2

Only read fixed length

Example

Only 4-8 characters are allowed to be read: scan the numeric setting barcode 0, 4, 0, 8, or 0, 8, 0, 4.

Fixed reading of 12 characters: Scan the numeric setting barcodes 1, 2, 1, 2.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F3118687F50000007.png

UCC/EAN-128 any length#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F0118687F50000007.png

UCC/EAN-128 specified length#

ISBT 128#

any length

Scan the appropriate barcode below to enable or disable ISBT 128.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000331.png

* Enable ISBT 128#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000330.png

any length#

Code 39#

Disable ISBT 128

Enable/disable Code 39#

Scan the corresponding barcode below to enable or disable Code 39.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000001.png

* Enable Code 39#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000000.png

Disable Code 39#

Code 39 length setting#

Allows reading of Code 39 codes of a specific length. After scanning the length setting barcode, scan the 4-digit setting barcode to set L1 and L2; L1 and L2 each occupy 2 digits. If there are less than 2 digits, add 0 in front.

When scanning the “Code 39 Any Length” setting barcode, any length can be read, and there is no need to scan the numeric setting barcode.

Default

0-99

Set range

01-99

condition

Description

L1 < L2

L1 is the minimum length, L2 is the maximum length

L1 > L2

L1 is the maximum length, L2 is the minimum length

L1 = L2

Only read fixed length

Example

Only 4-8 characters are allowed to be read: scan the numeric setting barcode 0, 4, 0, 8, or 0, 8, 0, 4.

Fixed reading of 12 characters: Scan the numeric setting barcodes 1, 2, 1, 2.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F3010001013700000.png

Code 39 any length#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F0010001013700000.png

Code 39 specifies the length#

Code 39 check digit verification#

When this feature is enabled, the reading engine checks the integrity of all Code 39 encodings to verify that the data conforms to the specified check digit algorithm. Only Code 39 encodings containing a modulo 43 check digit can be decoded. This feature can only be enabled if the Code 39 code format containing the modulo 43 check digit can be decoded.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020041.png

Verify Code 39 check digit#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020040.png

* Do not verify Code 39 check digit#

Transmit Code 39 Check Digit Scan this barcode to transmit the data check digit.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020241.png

Transmit Code 39 check digit#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020240.png

* Do not transmit Code 39 check digit#

Enable/disable Code 39 Full ASCII#

Code 39 Full ASCII is evolved from Code 39 and can encode double characters into Full ASCII characters. Scan the corresponding barcode below to enable or disable Code 39 Full ASCII.

See the mapping between Code 39 characters and ASCII values in Character Reference Table.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020111.png

Enable Code 39 Full ASCII#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020110.png

* Disable Code 39 Full ASCII#

Transmit Code 39 start and stop characters#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030300.png

* Disable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030301.png

Enable#

Convert Code 39 to Code 32 (Italian Medical Code)#

Code 32 is a Code 39 variant used in the Italian pharmaceutical industry. Scan the corresponding barcode below to enable or disable conversion from Code 39 to Code 32.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020300.png

* Disable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020301.png

Enable#

Code 32 prefix#

Enabling this parameter adds the prefix character “A” to all Code 32. Code 39 must be converted to Code 32 (Italian pharmaceutical code) before enabling this parameter.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020320.png

* Disable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020321.png

Enable#

Code 32 check code verification#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030190.png

* Disable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030191.png

Enable#

Transmit Code 32 check digit#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30301A0.png

* Transmit check digit 0x00#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30301A1.png

Enable transmission of Code 32 check digits#

Code 93#

Transmit start character, stop character, and check digit

0x01

Enable/disable Code 93#

Scan the corresponding barcode below to enable or disable Code 93.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000111.png

Enable Code 93#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000110.png

* Disable Code 93#

Set Code 93 length#

Allows reading of Code 93 codes of a specific length. After scanning the length setting barcode, scan the 4-digit setting barcode to set L1 and L2; L1 and L2 each occupy 2 digits. If there are less than 2 digits, add 0 in front.

When scanning the “Code 93 Any Length” setting barcode, any length can be read, and there is no need to scan the numeric setting barcode.

Default

0-99

Set range

01-99

condition

Description

L1 < L2

L1 is the minimum length, L2 is the maximum length

L1 > L2

L1 is the maximum length, L2 is the minimum length

L1 = L2

Only read fixed length

Example

Only 4-8 characters are allowed to be read: scan the numeric setting barcode 0, 4, 0, 8, or 0, 8, 0, 4.

Fixed reading of 12 characters: Scan the numeric setting barcodes 1, 2, 1, 2.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F3010A0B023700011.png

Code 93 any length#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F0010A0B023700011.png

Code 93 specifies the length#

Code 11#

Enable/disable Code 11#

Scan the corresponding barcode below to enable or disable Code 11.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000121.png

Enable Code 11#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000120.png

* Disable Code 11#

Code 11 length setting#

Allows reading of Code 11 codes of a specific length. After scanning the length setting barcode, scan the 4-digit setting barcode to set L1 and L2; L1 and L2 each occupy 2 digits. If there are less than 2 digits, add 0 in front.

When scanning the “Code 11 Any Length” setting barcode, any length can be read, and there is no need to scan the numeric setting barcode.

Default

4-99

Set range

01-99

condition

Description

L1 < L2

L1 is the minimum length, L2 is the maximum length

L1 > L2

L1 is the maximum length, L2 is the minimum length

L1 = L2

Only read fixed length

Example

Only 4-8 characters are allowed to be read: scan the numeric setting barcode 0, 4, 0, 8, or 0, 8, 0, 4.

Fixed reading of 12 characters: Scan the numeric setting barcodes 1, 2, 1, 2.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F3010C0D013700012.png

Code 11 any length#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F0010C0D013700012.png

Code 11 specifies the length#

Check code verification#

This feature allows the reading engine to check the integrity of all Code 11 encodings to verify that the data complies with the specified check digit algorithm. This will select the check digit mechanism for the decoded Code 11 barcode. Options include checking one parity digit, checking two parity digits, or disabling the feature.

To enable this feature, scan the Code 11 barcode below that matches the required number of check digits.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2051200.png

* Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2051201.png

a check digit#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2051202.png

two check digits#

Transmit Code 11 check digit#

Scan the barcode below to choose whether to transmit the Code 11 check digit.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020141.png

Transmit Code 11 check digit#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020140.png

* Code 11 check digit is not transmitted#

Note

In order for this parameter function to be implemented, Code 11 check code verification must be enabled.

Interleaved 2 of 5/ITF/Crossed 25 yards#

Enable/Disable Interleaved 2 of 5#

Scan the corresponding barcode below to enable or disable Interleaved 2 of 5.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000061.png

* Enable Interleaved 2 of 5#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000060.png

Disable Interleaved 2 of 5#

Interleaved 2 of 5 Length Settings#

Allows reading of Interleaved 2 of 5 codes of a specific length. After scanning the length setting barcode, scan the 4-digit setting barcode to set L1 and L2; L1 and L2 each occupy 2 digits. If there are less than 2 digits, add 0 in front.

When scanning the “Interleaved 2 of 5 arbitrary length” setting barcode, any length can be read, and there is no need to scan the numeric setting barcode.

Default

4-99

Set range

01-99

condition

Description

L1 < L2

L1 is the minimum length, L2 is the maximum length

L1 > L2

L1 is the maximum length, L2 is the minimum length

L1 = L2

Only read fixed length

Example

Only 4-8 characters are allowed to be read: scan the numeric setting barcode 0, 4, 0, 8, or 0, 8, 0, 4.

Fixed reading of 12 characters: Scan the numeric setting barcodes 1, 2, 1, 2.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F3010809024400006.png

Interleaved 2 of 5 any length#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F0010809024400006.png

Interleaved 2 of 5 specified length#

I 2 of 5 check code verification#

When enabled, this parameter checks the integrity of the I 2 of 5 symbology to ensure compliance with specified algorithms, including USS (Uniform Symbol Specification) or OPCC (Optical Product Code Council)

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2051E00.png

* Disable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/2051E01.png

Enable#

Transmit I 2 of 5 check digits#

Scanning this barcode transmits a checksum of the data.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020211.png

Transmit I 2 of 5 check digits#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020210.png

* Do not transmit I 2 of 5 check digits#

Discrete 2 of 5/Industrial 2 of 5/IND25/Industrial 25 yards#

Enable/disable Discrete 2 of 5#

Scan the corresponding barcode below to enable or disable Discrete 2 of 5.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000051.png

Enable Discrete 2 of 5#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000050.png

* Disable Discrete 2 of 5#

Discrete 2 of 5 Length Settings#

Allows reading of Discrete 2 of 5 codes of a specific length. After scanning the length setting barcode, scan the 4-digit setting barcode to set L1 and L2; L1 and L2 each occupy 2 digits. If there are less than 2 digits, add 0 in front.

When scanning the “Discrete 2 of 5 arbitrary length” setting barcode, any length can be read, and there is no need to scan the numeric setting barcode.

Default

4-99

Set range

01-99

condition

Description

L1 < L2

L1 is the minimum length, L2 is the maximum length

L1 > L2

L1 is the maximum length, L2 is the minimum length

L1 = L2

Only read fixed length

Example

Only 4-8 characters are allowed to be read: scan the numeric setting barcode 0, 4, 0, 8, or 0, 8, 0, 4.

Fixed reading of 12 characters: Scan the numeric setting barcodes 1, 2, 1, 2.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F3010607023700005.png

Discrete 2 of 5 any length#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F0010607023700005.png

Discrete 2 of 5 specified length#

Discrete 2 of 5 Verification#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030481.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030480.png

* Disable#

Discrete 2 of 5 Send check character#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030491.png

Enable Discrete 2 of 5 to send check characters#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030490.png

Disable Discrete 2 of 5 Send check characters#

Matrix 25(Matrix 25)#

Enable/disable Matrix 25#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030201.png

Enable Matrix 25#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030200.png

* Disable Matrix 25#

Matrix 25 check digit verification#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030211.png

Enable Matrix 25 checksum confirmation#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030210.png

* Disable Matrix 25 checksum confirmation#

Transmitting Matrix 25 check characters#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030221.png

Enable Matrix 25 transmission check characters#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030220.png

* Disable Matrix 25 transmission check characters#

Matrix 25 length setting#

Allows reading of Matrix 25 codes of specific lengths. After scanning the length setting barcode, scan the 4-digit setting barcode to set L1 and L2; L1 and L2 each occupy 2 digits. If there are less than 2 digits, add 0 in front.

When scanning the “Matrix 25 Any Length” setting barcode, any length can be read, and there is no need to scan the numeric setting barcode.

Default

4-99

Set range

01-99

condition

Description

L1 < L2

L1 is the minimum length, L2 is the maximum length

L1 > L2

L1 is the maximum length, L2 is the minimum length

L1 = L2

Only read fixed length

Example

Only 4-8 characters are allowed to be read: scan the numeric setting barcode 0, 4, 0, 8, or 0, 8, 0, 4.

Fixed reading of 12 characters: Scan the numeric setting barcodes 1, 2, 1, 2.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F3118081F50000001.png

Matrix 25 any length#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F0118081F50000001.png

Matrix 25 specifies the length#

Standard 25/IATA 25(Standard 25)#

Enable/disable Standard 25#

Scan the corresponding barcode below to enable or disable Standard 25.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030230.png

* Disable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030231.png

Enable#

Standard 25 check digit verification#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030240.png

* Disable Standard 25 checksum confirmation#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030241.png

Enable Standard 25 checksum confirmation#

Transmission check character#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030250.png

* Disable Standard 25 transmission check characters#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030251.png

Enable Standard 25 transmission check characters#

Standard 25 length setting#

Allows reading of Standard 25 codes of specific lengths. After scanning the length setting barcode, scan the 4-digit setting barcode to set L1 and L2; L1 and L2 each occupy 2 digits. If there are less than 2 digits, add 0 in front.

When scanning the “Standard 25 Any Length” setting barcode, any length can be read, and there is no need to scan the numeric setting barcode.

Default

4-99

Set range

01-99

condition

Description

L1 < L2

L1 is the minimum length, L2 is the maximum length

L1 > L2

L1 is the maximum length, L2 is the minimum length

L1 = L2

Only read fixed length

Example

Only 4-8 characters are allowed to be read: scan the numeric setting barcode 0, 4, 0, 8, or 0, 8, 0, 4.

Fixed reading of 12 characters: Scan the numeric setting barcodes 1, 2, 1, 2.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F3118283F50000003.png

Standard 25 any length#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F0118283F50000003.png

Standard 25 specified length#

Codabar#

Enable/disable Codabar#

Scan the corresponding barcode below to enable or disable Codabar.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000071.png

Enable Codabar#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000070.png

* Disable Codabar#

Codabar length setting#

Allows reading of Codabar codes of a specific length. After scanning the length setting barcode, scan the 4-digit setting barcode to set L1 and L2; L1 and L2 each occupy 2 digits. If there are less than 2 digits, add 0 in front.

When scanning the “Codabar Any Length” setting barcode, any length can be read, and there is no need to scan the numeric setting barcode.

Default

2-99

Set range

01-99

condition

Description

L1 < L2

L1 is the minimum length, L2 is the maximum length

L1 > L2

L1 is the maximum length, L2 is the minimum length

L1 = L2

Only read fixed length

Example

Only 4-8 characters are allowed to be read: scan the numeric setting barcode 0, 4, 0, 8, or 0, 8, 0, 4.

Fixed reading of 12 characters: Scan the numeric setting barcodes 1, 2, 1, 2.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F3010203023700007.png

Codabar any length#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F0010203023700007.png

Codabar specifies the length#

Codabar verification#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30304C1.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30304C0.png

* Disable#

Codabar sends check characters#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30304D1.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30304D0.png

* Disable#

NOTICE Edit#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020061.png

Enable NOTIS editing#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020060.png

* Disable NOTIS editing#

Start and stop character format#

The start and stop characters can each be one of A, B, C, or D. The stop character can also be one of T, N, *, or E.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030310.png

\* ABCD/ABCD#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030311.png

ABCD/TN*E#

Start and stop character letter case#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030320.png

* uppercase letter#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030321.png

lowercase letters#

MSI/MSI PLESSEY#

Enable/disable MSI#

Scan the corresponding barcode below to enable or disable MSI.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000141.png

Enable MSI#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000140.png

* Disable MSI#

MSI length settings#

Allows reading MSI codes of a specific length. After scanning the length setting barcode, scan the 4-digit setting barcode to set L1 and L2; L1 and L2 each occupy 2 digits. If there are less than 2 digits, add 0 in front.

When scanning the “MSI Any Length” setting barcode, any length can be read, and there is no need to scan the numeric setting barcode.

Default

2-99

Set range

01-99

condition

Description

L1 < L2

L1 is the minimum length, L2 is the maximum length

L1 > L2

L1 is the maximum length, L2 is the minimum length

L1 = L2

Only read fixed length

Example

Only 4-8 characters are allowed to be read: scan the numeric setting barcode 0, 4, 0, 8, or 0, 8, 0, 4.

Fixed reading of 12 characters: Scan the numeric setting barcodes 1, 2, 1, 2.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F3010F10013700014.png

MSI arbitrary length#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F0010F10013700014.png

MSI specified length#

MSI check digit#

These check digits at the end of the barcode verify data integrity. At least one check digit is always required, and check digits are not transmitted with the data automatically. If you select two check digits, you must also set the MSI check digit algorithm.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020120.png

* An MSI check digit#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020121.png

Two MSI check digits#

Transmit MSI check code#

Scan this barcode to be set to transmit a checksum with data.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020131.png

Transmit MSI check code#

Scan this barcode to set up data transmission without a checksum.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020130.png

* MSI check code is not transmitted#

MSI check code algorithm#

When selecting two MSI check digits, one of the following algorithms needs to be selected.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020230.png

MOD 10 / MOD 11#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1020231.png

\* MOD 10 / MOD 10#

GS1 DataBar/RSS#

Enable/disable GS1 DataBar/RSS#

Scan the corresponding barcode below to enable or disable GS1 DataBar/RSS.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000351.png

Enable GS1 DataBar/RSS#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000350.png

* Disable GS1 DataBar/RSS#

RSS AI characters#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030261.png

* Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030260.png

Disable#

PDF417#

Enable/disable PDF417#

Scan the corresponding barcode below to enable or disable PDF417.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000170.png

Disable PDF417#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1000171.png

* Enable PDF417#

PDF417 positive/negative reading#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030610.png

* read only positive#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030611.png

Read only invert#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030612.png

Both forward and reverse phases can be read.#

QR Code#

Enable/disable QR Code#

Scan the corresponding barcode below to enable or disable QR Code.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1003250.png

Disable QR Code#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1003251.png

* Enable QR Code#

ECI control#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030660.png

* ECI does not output#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030661.png

ECI output#

QR positive/reverse phase reading#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030670.png

* read only positive#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030671.png

Read only invert#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030672.png

Both forward and reverse phases can be read.#

Remove UTF-8 BOM encoding format of QR Code#

When enabled, UTF-8 BOM encoding format is removed when outputting QR Code data.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/6063A00.png

* Disable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/6063A01.png

Enable#

Data Matrix (DM)#

Both normal images and mirror images can be read.

Enable/disable Data Matrix (DM)#

Scan the corresponding barcode below to enable or disable the Data Matrix (DM).

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1003240.png

Disable Data Matrix#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1003241.png

* Enable Data Matrix#

Positive/negative reading#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30306B0.png

* read only positive#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30306B1.png

Read only invert#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30306B2.png

Both forward and reverse phases can be read.#

ECI control#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30306C0.png

* ECI does not output#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/30306C1.png

ECI output#

Maxi Code#

Enable/disable Maxi Code#

Scan the corresponding barcode below to enable or disable Maxi Code.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1003260.png

* Disable Maxi Code#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1003261.png

Enable Maxi Code#

Aztec Code#

Enable/disable Aztec Code#

Scan the corresponding barcode below to enable or disable Aztec Code.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1003280.png

* Disable Aztec Code#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/1003281.png

Enable Aztec Code#

Han Xin Code#

Enable/disable Han Xin Code#

Scan the corresponding barcode below to enable or disable Han Xin Code.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/10032F0.png

* Disable Han Xin Code#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/10032F1.png

Enable Han Xin Code#

Positive/negative reading#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030710.png

* read only positive#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030711.png

Read only invert#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030712.png

Both forward and reverse phases can be read.#

ISSN#

Converts to EAN-13 when disabled.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030330.png

* Disable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030331.png

Enable#

NEC-25(COOP25)#

NEC-25(COOP25) switch

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030451.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030450.png

* Disable#

NEC-25(COOP25) Verification#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030461.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030460.png

* Disable#

NEC-25(COOP25) Send check character#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030471.png

Enable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030470.png

* Disable#

NEC-25 (COOP 25) length setting#

Allows reading of NEC-25 codes of specific lengths. After scanning the length setting barcode, scan the 4-digit setting barcode to set L1 and L2; L1 and L2 each occupy 2 digits. If there are less than 2 digits, add 0 in front.

When scanning the “NEC-25 Any Length” setting barcode, any length can be read, and there is no need to scan the numeric setting barcode.

Default

4-99

Set range

01-99

condition

Description

L1 < L2

L1 is the minimum length, L2 is the maximum length

L1 > L2

L1 is the maximum length, L2 is the minimum length

L1 = L2

Only read fixed length

Example

Only 4-8 characters are allowed to be read: scan the numeric setting barcode 0, 4, 0, 8, or 0, 8, 0, 4.

Fixed reading of 12 characters: Scan the numeric setting barcodes 1, 2, 1, 2.

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F3118889F50000009.png

NEC-25 any length#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/F0118889F50000009.png

NEC-25 specified length#

COMPOSITE#

Enable/disable COMPOSITE

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030170.png

* Disable#

https://cdn.scandocs.net/scanner/manual/global/_shared/_images/module-212/3030171.png

Enable#