Trigger settings#
reading mode#
Users can set the reading mode of the scan engine according to their needs. The default state is the button trigger mode. In this mode, the scan engine starts reading after pressing the trigger button, and stops reading after successful reading or releasing the trigger button.
* Key Trigger#
Users can also set the scan engine to automatic continuous reading mode. After the setting is successful, the red light of the scan engine is always on. When a barcode passes by, the scan engine automatically reads the barcode. The same barcode will not be read again unless it is removed and read again.
Automatic Continuous Reading#
Discontinuous Reading#
The user can also set the scan engine to the button delay mode. After the setting is successful, the red light of the scan engine will stay on for 3 seconds, and the light will turn off if the scan engine is not read after a timeout of 3 seconds, or the light will turn off after the reading is successful. The key timeout is
Key Delay#
Key Delay Parameters#
Key Timeout#
When the user uses the key delay mode, the user can set the decoding timeout according to the needs. The default is 3 s and the time range is 1-9.9 s.
Timeout 1 S#
* Timeout 3 S#
Timeout 5 S#
Timeout 9.9 s#
Self-sensing Settings#
* Disable IR Auto-sensing#
Enable IR Auto-sensing#
Self-sensing Sensitivity And Interval Time Parameters
- Format
0265 + sensitivity setting + interval setting- Sensitivity
0x01to0xFF, the smaller the value, the higher the sensitivity.- Interval time
0x01to0x40.- Example
02657705means the sensitivity is0x77and the interval is0x05(500 ms).
Self-sensing Sensitivity And Interval Time Setting Example#
Inverse Color Reading Settings#
Enable Inverse Color Reading#
* Disable Inverse Color Reading#
Inverse Color Reading Settings#
Duplicate Code Detection Settings#
* Disable Duplicate Code Detection#
Enable Duplicate Code Detection#
The Re-coding Interval Is 1s#
The Re-code Interval Is 2s#
The Re-code Interval Is 3s#
The Re-coding Interval Is 5s#
The Re-coding Interval Is 10s#